Got an ICV? Regulating the Pressure is EZ!

Take a look at the article "Accu-Set™ Takes the Pressure Out of Selecting the Right Valve" and you'll understand the importance of a pressure regulator when installing sprinklers at commercial sites that have high incoming water pressure.

Quite often on these types of sites, however, valves will be located a great distance apart and a system pressure regulator won't work properly due to the variances in pressure that occur in long pipe runs. The Accu-Set pressure regulator, an option available on all Hunter ICV valve models, has been designed to provide just the solution for such a situation.

The Accu-Set can be factory installed whenever purchasing ICV valves or you can do the easy field installation on to existing ICV valves in a few simple steps:

Installing the Accu-Set Pressure Regulator

  1. Remove the solenoid from the Hunter ICV irrigation valve. (Also remove the flow control knob on the 1" ICV.
  2. Thread the solenoid onto the Accu-Set.
  3. Before threading, align the Accu-Set over the solenoid seat and position the Schrader valve portion of the Accu-Set towards the flow control handle.
  4. Thread the Accu-Set into the solenoid area of the ICV.

Remove the solenoid from the Hunter ICV irrigation valve. Thread the solenoid onto the Accu-Set.

Turn the clear dial on the top of the Accu-Set until the arrow underneath the clear dial is pointing to the desired downstream pressure.Setting the Accu-Set Pressure Regulator

  1. Turn the clear dial on the top of the Accu-Set until the arrow underneath the clear dial is pointing to the desired downstream pressure.
  2. The white colored scale is for "PSI," the yellow colored scale is for "bar."
Ligações Relacionadas
Accu-Set™ Takes the Pressure Out of Selecting the Right Valve
Pesquisar no Site